SMART電源エラーの説明

SMART電源エラーの説明

私はgsmartcontrol「エラー」タブを使用していますが、次のように言います。

Complete error log:

SMART Error Log Version: 1
ATA Error Count: 398 (device log contains only the most recent five errors)
    CR = Command Register [HEX]
    FR = Features Register [HEX]
    SC = Sector Count Register [HEX]
    SN = Sector Number Register [HEX]
    CL = Cylinder Low Register [HEX]
    CH = Cylinder High Register [HEX]
    DH = Device/Head Register [HEX]
    DC = Device Command Register [HEX]
    ER = Error register [HEX]
    ST = Status register [HEX]
Powered_Up_Time is measured from power on, and printed as
DDd+hh:mm:SS.sss where DD=days, hh=hours, mm=minutes,
SS=sec, and sss=millisec. It "wraps" after 49.710 days.

Error 398 occurred at disk power-on lifetime: 125 hours (5 days + 5 hours)
  When the command that caused the error occurred, the device was active or idle.

  After command completion occurred, registers were:
  ER ST SC SN CL CH DH
  -- -- -- -- -- -- --
  84 51 01 0f 08 00 00  Error: ICRC, ABRT at LBA = 0x0000080f = 2063

  Commands leading to the command that caused the error were:
  CR FR SC SN CL CH DH DC   Powered_Up_Time  Command/Feature_Name
  -- -- -- -- -- -- -- --  ----------------  --------------------
  60 10 00 00 08 00 40 00      00:09:15.084  READ FPDMA QUEUED
  ec 00 00 00 00 00 00 00      00:09:15.006  IDENTIFY DEVICE
  ef 10 03 00 00 00 00 00      00:09:14.990  SET FEATURES [Enable SATA feature]
  ef 10 02 00 00 00 00 00      00:09:14.974  SET FEATURES [Enable SATA feature]
  b1 c1 00 00 00 00 00 00      00:09:14.959  DEVICE CONFIGURATION FREEZE LOCK [OBS-ACS-3]

Error 397 occurred at disk power-on lifetime: 125 hours (5 days + 5 hours)
  When the command that caused the error occurred, the device was active or idle.

  After command completion occurred, registers were:
  ER ST SC SN CL CH DH
  -- -- -- -- -- -- --
  84 51 01 0f 08 00 00  Error: ICRC, ABRT at LBA = 0x0000080f = 2063

  Commands leading to the command that caused the error were:
  CR FR SC SN CL CH DH DC   Powered_Up_Time  Command/Feature_Name
  -- -- -- -- -- -- -- --  ----------------  --------------------
  60 10 00 00 08 00 40 00      00:09:14.756  READ FPDMA QUEUED
  ec 00 00 00 00 00 00 00      00:09:14.678  IDENTIFY DEVICE
  ef 10 03 00 00 00 00 00      00:09:14.662  SET FEATURES [Enable SATA feature]
  ef 10 02 00 00 00 00 00      00:09:14.646  SET FEATURES [Enable SATA feature]
  b1 c1 00 00 00 00 00 00      00:09:14.631  DEVICE CONFIGURATION FREEZE LOCK [OBS-ACS-3]

Error 396 occurred at disk power-on lifetime: 125 hours (5 days + 5 hours)
  When the command that caused the error occurred, the device was active or idle.

  After command completion occurred, registers were:
  ER ST SC SN CL CH DH
  -- -- -- -- -- -- --
  84 51 01 0f 08 00 00  Error: ICRC, ABRT at LBA = 0x0000080f = 2063

  Commands leading to the command that caused the error were:
  CR FR SC SN CL CH DH DC   Powered_Up_Time  Command/Feature_Name
  -- -- -- -- -- -- -- --  ----------------  --------------------
  60 10 00 00 08 00 40 00      00:09:14.508  READ FPDMA QUEUED
  60 01 00 02 00 00 40 00      00:09:14.506  READ FPDMA QUEUED
  60 04 00 07 00 00 40 00      00:09:14.506  READ FPDMA QUEUED
  60 01 00 00 00 00 40 00      00:09:14.506  READ FPDMA QUEUED
  60 01 00 00 00 00 40 00      00:09:14.506  READ FPDMA QUEUED

Error 395 occurred at disk power-on lifetime: 125 hours (5 days + 5 hours)
  When the command that caused the error occurred, the device was active or idle.

  After command completion occurred, registers were:
  ER ST SC SN CL CH DH
  -- -- -- -- -- -- --
  84 51 01 0f 88 b9 0a  Error: ICRC, ABRT at LBA = 0x0ab9880f = 179931151

  Commands leading to the command that caused the error were:
  CR FR SC SN CL CH DH DC   Powered_Up_Time  Command/Feature_Name
  -- -- -- -- -- -- -- --  ----------------  --------------------
  60 10 00 00 88 b9 40 00      00:00:15.234  READ FPDMA QUEUED
  ec 00 00 00 00 00 00 00      00:00:15.156  IDENTIFY DEVICE
  ef 10 03 00 00 00 00 00      00:00:15.141  SET FEATURES [Enable SATA feature]
  ef 10 02 00 00 00 00 00      00:00:15.125  SET FEATURES [Enable SATA feature]
  b1 c1 00 00 00 00 00 00      00:00:15.109  DEVICE CONFIGURATION FREEZE LOCK [OBS-ACS-3]

Error 394 occurred at disk power-on lifetime: 125 hours (5 days + 5 hours)
  When the command that caused the error occurred, the device was active or idle.

  After command completion occurred, registers were:
  ER ST SC SN CL CH DH
  -- -- -- -- -- -- --
  84 51 01 57 d1 54 08  Error: ICRC, ABRT at LBA = 0x0854d157 = 139776343

  Commands leading to the command that caused the error were:
  CR FR SC SN CL CH DH DC   Powered_Up_Time  Command/Feature_Name
  -- -- -- -- -- -- -- --  ----------------  --------------------
  60 08 00 50 d1 54 40 00      00:00:14.984  READ FPDMA QUEUED
  ec 00 00 00 00 00 00 00      00:00:14.922  IDENTIFY DEVICE
  ef 10 03 00 00 00 00 00      00:00:14.906  SET FEATURES [Enable SATA feature]
  ef 10 02 00 00 00 00 00      00:00:14.891  SET FEATURES [Enable SATA feature]
  b1 c1 00 00 00 00 00 00      00:00:14.875  DEVICE CONFIGURATION FREEZE LOCK [OBS-ACS-3]

スマートプロパティ

どういう意味ですか?このエラーを防ぐ方法は?

ベストアンサー1

「ICRCの間違い」とは、次のことを意味します。転送中にデータが破損しています。;ドライブの寿命を考慮すると、最も可能性の高い原因は損傷したケーブルです。全体的に考えられる原因は次のとおりです。

  • ケーブルが破損しています。問題が解決しない場合は、ケーブルを再取り付けして交換してみてください。
  • 不良チップセット(マザーボードが非常に古くない場合の可能性は低い)
  • 運転がうまくいかない。

最後のステップに達したら、別のシステムでドライブを試してみてください。

おすすめ記事